Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 07/18
99
SR Flip Flop
SR FLIP FLOP operator brings output Q at 1
with Set, 0 with Reset.
See the following truth table.
Set
Reset
Q
0
0
Keep memory
0
1
0
1
0
1
1
1
0
User Restart Manual (max number= 16 with restart monitored)
The USER RESTART MANUAL operator
saves the restart signal according to the
following truth table.
Set
Reset
Q
0
0
Keep memory
0
1
0
1
0
1
1
1
0
Parameters
Clear enable: If selected enables the saving process to be reset.
User Restart Monitored (max number= 16 with restart manual)
The USER RESTART MONITORED operator
is used to save the restart signal according
to the following truth table.
Clear
Restart
In
Q
1
X
X
X
X
X
0
0
0
L
1
0
0
Rising Edge
1
Keep memory
0
1
1
Parameters
Clear enable: If selected enables the saving process to be reset.
CERTUS Installation Manual