CDE360 Vector Control AC Drive Chapter 4 Operation,Display and Application
-
41
-
4.4 Menu Introduction
Three level menu:
Level 1 : like
—b2—
, function code group, the group name will display on the LCD screen.
Level 2 :
like
b2.01
, function code, the function code name will display on the LCD screen.
Level 3 : like
50.00
, function code setting value, the value range will display on the LCD
screen.
Enter menu, the blinking digit can be modified by rotating the Rotary knob, and can be
switched to another digit by pressing
SHIFT
key
Return to Level 2 menu from Level 3 by pressing
PRG
or
ENTER
.
Pressing
Enter
key will save the parameter value, and go to the next parameter in Level
2 menu.
Pressing
PRG
key will not save the parameter value, and just return to current parameter
in Level 2 menu.
50.00
—H0—
H0.XX
0000
PRG
PRG
PRG
Enter
Enter
PRG
Enter
Change Group
Viewing
Parameters Status
Level 1
Change
function code
Level 2
Change
parameter value
Level 3
Figure 4- 3
The three-level menu operation procedure
In Level 3 menu, the digit to be modified change from low digit to high digit when use
SHIFT
key. When the parameter reaches maximum or minimum value,it
can’t be increased or
decreased.
In Level 3 menu, if the parameter has no blinking digit, it means that the parameter cannot be
modified. This may cause by:
1) This is a read-only parameter,such as the monitor parameters.
2) This parameter cannot be modified in the running state,such as the motor related parameters.
4.5 Monitor Parameters
After power on the AC drive
, monitor parameters can be displayed through
SHIFT
key. And
the parameters H0.01, H0.02, and H0.03 determine which monitor parameter can be displayed.
Total of 24 monitor parameters can be displayed in running state. Total of 13 monitor parameters
can be displayed in stop state.