CDE360 Vector Control AC Drive Chapter 6 Parameters Description
Group H0: System Parameters
H0.00
Range: 0000~9999
Default: 0000
User password
If it is set to any non-zero number, the password protection function is
enabled. After a password has been set and taken effect, you must enter
the correct password in order to enter the menu. If the entered password
is incorrect you cannot view or modify parameters.
You can set the user password successfully when you set the same
value(none zero) two times to
H0.00
. If the user password has been set
successfully then the LED will display “P.Set”.
If you want to clear the user password then set zero the
H0.00
two times.
If you clear the user password successfully then the LED will display
“P.CLr”.
H0.01
Range: 0~65535
Default: 31
LED display
running
parameters 1
In the stop or running state, you can press shift key on the keypad to
display monitor parameters. Whether parameters are displayed is
determined by the binary bits of values converted from the values of
H0.01
~
H0.03
in the decimal format.
Bit0: running freq(1)
Bit1: setting freq(2)
Bit2: Dc-link voltage(4)
Bit3: output current(8)
Bit4: output voltage(16)
Bit5: output torque(32)
Bit6: output power(64)
Bit7: AI1 voltage(128)
Bit8: AI2 voltage(256)
Bit9: AI3 voltage(512)
Bit10: X terminal status(1024)
Bit11: Y terminal status(2048)
Bit12: PLC stage(4096)
Bit13: PID setting(8192)
Bit14: PID feedback(16384)
Bit15: count value(32768)
H0.02
Range: 0~2047
Default: 0
LED display
running
parameters 2
Bit0: FI input freq(1)
Bit1: Linear speed(2)
Bit2: Load speed(4)
Bit3: Length value(8)
Bit4: Remaining running time(16)
Bit5: Main frequency A display(32)
Bit6: Auxiliary frequency B display(64)
Bit7: FO output freq(128)
Bit8: Feedback freq(256)
Bit9: motor speed (512)
Bit10: Multi-Pump Control status words(1024)
H0.03
Range: 0~65535
Default: 3
LED display stop
parameters
Bit0: setting freq(1)
Bit1: Dc-link voltage(2)
Bit2: X terminal status(4)
Bit3: Y terminal status(8)
Bit4: AI1 voltage(16)
Bit5: AI2 voltage(32)
Bit6: AI3 voltage(64)
Bit7: FI input freq(128)
Bit8: PID feedback(256)
Bit9: PID feedback(512)
Bit10: PLC stage(1024)
Bit11: pulse count(2048)
Bit12: Length value(4096)
Bit13
~
Bit15: reverse