CDE360 Vector Control AC Drive Chapter 6 Parameters Description
-
91
-
A0.34
Range: 0~65535
Default: 0
Phase z counting
It displays the phase Z counting of the current ABZ or UVW encoder. The
value increases or decreases by 1 every time the encoder rotates one
revolution forwardly or reversely.
A0.35
Range: 0~4095
Default: 0
Resolver position
It displays the current resolver position.
A0.36
Range: 0~
b0.07
Default: 0
Reference
voltage for V/F
separation
Unit: V
They display the Reference output voltage in the V/F separation state.
A0.37
Range: 0~
b0.07
Default: 0
Output voltage
for V/F
separation
Unit: V
They display the actual output voltage in the V/F separation state.
A0.38
Range: -300.0~300.0
Default: 0.0
Target torque
Unit: %
It displays the current torque upper limit.
A0.39
Range: 0.0~300.0
Default: 0.0
Upper torque
limit
Unit: %
It displays the current setting torque upper limit
A0.40
Range: -100.00~100.00
Default: 0.00
Communication
setting
Unit: %
It displays the data written by means of the communication address
0x6400.
A0.41
Range: -100.0~100.0
Default: 0.0
Point-to-point
send data
Unit: %
It displays the data send by master in master-slave communication mode.
A0.42
Range: -100.0~100.0
Default: 0.0
Point-to-point
receive data
Unit: %
It displays the data received by slave in master-slave communication
mode.
A0.52
Range: 0~65535
Default: 0
Power-on time
Unit: Min
It is used to display the current power-on time of the drive, the unit is 1
minute.