CDE360 Vector Control AC Drive Chapter 6 Parameters Description
d3.04
Range: -300.0 ~ 300.0
Default: 0.0
Digital setting of
torque
compensation
Unit: %
Digital setting of torque compensation. 100% of the setting corresponds to
the rated motor torque.
Torque reference
d3.01
,
d3.02
Torque
compensation
d3.03
,
d3.04
Speed limit
d3.05
–
d3.11
Target torque
A0.37
Internal torque
reference
Figure 6- 25 torque reference for torque control
d3.05
①
Range: 0 ~ 5
Default: 0
Speed limit mode
Speed limit mode selection for torque control.
0: Minimum frequency to maximum frequency
1: Minimum frequency to running frequency
2: Negative running frequency to positive running frequency
3: Running frequency to maximum frequency
4: Running fre windows
5: 0Hz to output frequency
In torque control, motor rotor speed should be limit within suitable range to avoid that the speed
is out of control. When rotor speed is within the setting range, torque control is active. Otherwise,
speed control will be active when speed is out of the setting range.
d3.06
①
Range: 0 ~ 7
Default: 0
Maximum
frequency source
maximum frequency source:
0: d3.07
1: AI1
2: AI2
3: AI3
4: X6/FI
5: Communication
6: MIN
(
AI1,AI2
)
7: MAX
(
AI1,AI2
)
When this parameter is set to 0, maximum frequency is set by d3.07.
When this parameter is set to none 0, 100% of the setting corresponds to
the value of d3.07.