CDE360 Vector Control AC Drive Chapter 5 Parameter List Table
-
48
-
Function
Code
Name
Range
Default
Step
Description
A0.33
Encoder
detection speed
-320.00~320.00
0.00
0.01Hz
indicate the motor speed from
Encoder detection
A0.34
Z pulse counter
0~65535
0
1
A0.35
Resolver position
0~4095
0
1
A0.36
Reference
voltage for V/f
separation
0~b0.07
0
1V
A0.37
Output voltage
for V/f separation
0~b0.07
0
1V
A0.38
Target torque
-300.0~300.0
0.0
0.1%
Target torque which is used in
torque control mode
A0.39
Upper torque
limit
0.0~300.0
0.0
0.1%
The max allowable torque in
vector control mode
A0.40
Communication
setting
-100.00~100.00
0.00
0.01%
Display the value located in
0x6400 sent by communication.
A0.41
Point-to-point
send data
-100.00~100.00
0.00
0.01%
Indicate the data sent from
master in point to point control
mode
A0.42
Point-to-point
receive data
-100.00~100.00
0.00
0.01%
Indicate the data received by
slave in point to point control
mode
A0.52
Power on time
0~65535
0
1Min
Current power on time, its unit
is Min
A0.53
Running time
0.0~6553.5
0.0
0.1Min
Current running time, its unit is
0.1Min
A0.54
Accumulative
power-on day
0~9999
0
1Day
A0.55
Accumulative
power-on hour
0.00~23.99
0.00
0.01h
A0.56
Accumulative
running day
0~9999
0
1Day
A0.57
Accumulative
running hour
0.00~23.99
0.00
0.01h
A0.58
Accumulative
power
consumption
0~65535
0
1kwh