CDE360 Vector Control AC Drive Chapter 6 Parameters Description
输出电流
零电流检测水平
F8.23
时间
t
时间
t
零电流检测
信号
零电流检出时间
F8.24
ON
Figure 6- 55 Zero current detection diagram
Eb.19
Range: 0.0~300.0
Default: 200.0
Output over
current threshold
Unit: %
This is a relative value to
b0.08
(motor rated current).
If the output current of the AC drive is equal to or higher than
Eb.19
*
b0.08
and the duration exceeds
Eb.20
,the Y terminal allocated with function
No.34 “Current limit exceeded” becomes ON. The output over current
detection function is shown in the following figure.
Eb.20
Range: 0.00~600.00
Default: 0.00
Output over
current detection
delay time
Unit: Sec
Please see the description of the following figure.
输出电流
输出电流超限值
输出电流超
限检测信号
输出电流超
限延迟时间
ON
时间
t
时间
t
Figure 6- 56 Output over current detection diagram
Eb.21
Range: 0.0~300.0
Default: 100.0
Any current
reaching 1
Unit: %
This is a relative value to
b0.08
(motor rated current).
If the output current of the AC drive is within the positive and negative
amplitudes of
Eb.21
*
b0.08
, the Y terminal allocated with function No.28
“Current 1 reached” becomes ON.
The any current detection function is shown in the following figure.