
8
8
8-154
8-154
Service Mode > COPIER > OPTION > CUSTOM
Service Mode > COPIER > OPTION > CUSTOM
COPIER > OPTION > CUSTOM
AC-FREQ
Setting of frequency of AC power
Lv.2 Details
Although power frequency is judged for power control with the
machine, it might be judged incorrectly depending on power
circumstance at the installation location.
At left side column, the power frequency (50 Hz/60 Hz) which the DC
Controller judged at power-on is displayed.
In the case that the power frequency is not matched with the one
at the installation location, set the AC power frequency at right side
column.
Use case
When the breaker is frequently tripped during operation
Adj/set/operate method 1) Select the right side column.
2) Enter the setting value, and then press OK key.
Display/adj/set range
Left side: 0 to 1
0: 50 Hz, 1: 60 Hz
Right side: 0 to 2
0: Judged frequency is used, 1: 50 Hz, 2: 60 Hz
Default value
0
T-8-65
Summary of Contents for imageRUNNER ADVANCE 6075 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...