9
9
9-248
9-248
Installation > [TYPE-8] Option HDD (80GB) + Removable HDD Kit + HDD Mirroring Kit or HDD Data Encryption & Mirroring Kit > Installation Procedure > Changing Configuration inside of HDD Case Unit
Installation > [TYPE-8] Option HDD (80GB) + Removable HDD Kit + HDD Mirroring Kit or HDD Data Encryption & Mirroring Kit > Installation Procedure > Changing Configuration inside of HDD Case Unit
■
Changing Configuration inside of HDD Case Unit
1) Remove the E-ring from the removed HDD Case Unit, remove the shaft of the HDD Cap,
and then remove the HDD Fixed Plate. (The removed HDD Fixed Plate will not be used.)
HDD Fixed Plate
2) Put the HDD Cap and the shaft back to the HDD Case Unit, and secure the HDD Case Unit
with the E-ring.
3) Remove the Face Plate. (The removed Face Plate will not be used.)
• 1 Screw
F-9-501
F-9-502
4) Remove the Upper Rail from the HDD Case Unit.
• 2 Screws (The removed screws will be used in step 7).)
x2
5) Remove the Leaf Spring from the removed rail in the order of the arrows in the figure
below. (The removed Leaf Spring will not be used.)
• 2 Bosses
• 2 Arms
Boss
Turn over
Boss
Arm
F-9-503
F-9-504