6
6
6-33
6-33
Troubleshooting > Controller Self Diagnosis > Operation > Diagnosis Time
Troubleshooting > Controller Self Diagnosis > Operation > Diagnosis Time
2) Right after the Main Power Supply Lamp lights up once, it lights out instantly, and diagnosis
starts.
(When the Main Power Supply Lamp lights out, you can release your finger from the
Control Panel Switch.)
Processing/Date Error
Clear
Reset
Stop
Start
Main Menu
Quick Menu
Status Monitor/Cancel
Settings/Registration Energy Saver
Log In/Out
■
Diagnosis Time
Diagnosis is completed in approx. 1 minute.
<When the diagnosis result is normal>
After the Main Power Supply Lamp repeatedly lights out 5 times, it lights up and the diagnosis
is completed.
After completion of the diagnosis, this machine executes normal boot sequence.
F-6-59
F-6-60
<When an error is detected by diagnosis>
The Main Power Supply Lamp repeats high-speed blinking after completion of a check in
which an error is detected. (See *1.)
For example, when an error is detected in Check 2, the Main Power Supply Lamp lights out
twice and repeats high-speed blinking (ON/OFF in 0.3 seconds interval).
When an error is detected, be sure to count the number of times the Main Power Supply
Lamp lights out.
For detailed results, see "Error Diagnosis".
*1: When an error is detected, there is a possibility that the Main Power Supply Lamp may not
perform high-speed blinking but perform other operation (continuous light-up, light-out). In
this case, remove and then install the 2 SDRAMs on the Main Controller PCB 1.
If the error is not resolved, execute the remedy of the Check No. which is not completed
normally. (For details, see "Error Diagnosis".)
*2: Although diagnosis time for Check 3, and Check 4 is longer than that of other Checks, it is
correct operation.
*3: When the 2 SDRAMs are not mounted on the Main Controller PCB 1, this diagnosis is not
completed. In this case, install the appropriate 2 SDRAMs.
F-6-61
Summary of Contents for imageRUNNER ADVANCE 6075 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...