2
2
2-102
2-102
Technology > Fixing > Controls > Fixing temperature control
Technology > Fixing > Controls > Fixing temperature control
●
Temperature control during startup
Temperature is controlled to reach the standby temperature.
0
10
20
30
40
50
60
70
80
5
10
15
20
25
30
35
Low temperature environment
startup mode
Environment humidity(%)
Environment temperature (deg C)
Normal startup mode
High humidity environment
startup mode
<Normal startup mode>
In the case of reaching the target temperature within 30 seconds due to quick temperature
rise of the Fixing Roller, the target temperature is maintained to be shifted to the ready
state once the potential control is completed.
Conditions
Target
temperature
Target
temperature
reaching
time
Environment
temperature
Environment
humidity
Fixing Roller
temperature
17 deg C or
more
Low humidity
environment(within
13g of absolute
moisture content)
70 deg C or
less
Japanese model
imageRUNNER ADVANCE
6055: 180 deg C
30 sec
NOTE:
In the case of selecting the fixing improvement mode in the following service mode, the
machine does not enter the startup state for 30 seconds and waits until the specified
time.
COPIER> OPTION> BODY> FSPD-S1 :Selection of fixing improvement mode
F-2-132
T-2-55
<Low temperature environment startup mode>
After it reaches the target temperature, the target temperature is maintained until
completion of the potential control, and then the machine enters ready state.
Conditions
Target
temperature
Target
temperature
reaching time
Environment
temperature
Environment humidity
Fixing Roller
temperature
Less than 17
deg C
-
70 deg C or less 195 deg C
75 sec
(reference value)
<High humidity environment startup mode>
After it reaches the target temperature, the target temperature is maintained until
completion of developing idle rotation as well as completion of the potential control, and
then the machine enters ready state.
Conditions
Target
temperature
Target
temperature
reaching time
Environment
temperature
Environment humidity
Fixing Roller
temperature
-
High humidity
environment(13g or more
of absolute moisture
content)
70 deg C or less 185 deg C
<imageRUNNER
ADVANCE
6055 Japanese
model:180 deg
C>
75sec
(reference value)
<Recovery mode>
The machine enters ready state once it reaches the target temperature.
Conditions
Target temperature
Target
temperature
reaching time
Environment
temperature
Environment
humidity
Fixing Roller
temperature
-
-
70 deg C or
more
Environment Temperature: 17
deg C or more
Japanese: 180 deg C
(imageRUNNER ADVANCE
6055: 175 deg C)
Non Japanese: 185 deg C
Environment Temperature: less
than 17 deg C
Japanese: 190 deg C
Non Japanese: 195 deg C
30 sec or less
T-2-56
T-2-57
T-2-58
Summary of Contents for imageRUNNER ADVANCE 6075 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...