7
7
7-12
7-12
Error Code > Error Code > Error Code Details > E000 to E069
Error Code > Error Code > Error Code Details > E000 to E069
E
Code
Detail
Code
Location
Item
Description
E067 -0001
-05
Title
Developing high voltage output leak error
Remedy
1. Check the connection between the Main Driver PCB (PCB2)
and the High Voltage Unit.
Main Driver side: J112, High Voltage Unit side: J3098
2. Check the connection between the Relay PCB (PCB5) and
the High Voltage Unit.
Relay side: J519, High Voltage Unit side: J3099
3. Replace the Developing Assembly.
4. Check the connection point of the Developing Assembly.
If it is soiled, clean it.
5. Check the connection inside of the High Voltage Unit.
Check the connection of the High Voltage Unit Relay
(J3097) and the Developing High Voltage PCB (J3511).
High Voltage Unit Relay (J3099) and Pre-transfer Charging
PCB (J3545, J3500, J3510)
6. Replace the Main Driver PCB (PCB2).
Description The leak detection signal was detected 5 times in a row for
every 20 msec.
E068 -0001
-05
Title
Pre-transfer charging high voltage output leak error
Remedy
1. Check the connection between the Main Driver PCB (PCB2)
and the High Voltage Unit.
Main Driver side: J112, High Voltage Unit side: J3098
2. Check the connection between the Relay PCB (PCB5) and
the High Voltage Unit.
Relay side: J519, High Voltage Unit side: J3099
3. Replace the Pre-transfer Charging Assembly.
4. Check the connection inside of the High Voltage Unit.
Check the connection of the High Voltage Unit Relay
(J3098) and the Transfer High Voltage PCB (J3544).
Check the connection of the High Voltage Unit Relay
(J3099) and the Pre-transfer Charging PCB (J3545, J3500)
5. Replace the Main Driver PCB (PCB2).
6. Replace the Pre-transfer High Voltage Connector (FM4-
1007).
7. Replace the Pre-transfer Transformer (Post Charging
Trance) of the High Voltage Unit.
Description The leak detection signal was detected 5 times in a row for
every 20 msec.
E
Code
Detail
Code
Location
Item
Description
E069 -0001
-05
Title
Transfer high voltage output leak error
Remedy
1. Check the connection between the Duplex Driver PCB
(PCB4) and the High Voltage Unit.
Check the connection at Duplex Driver side (J343) and the
Transfer High Voltage side (J3066).
Check the connection at Duplex Driver side (J311) and the
Transfer High Voltage side (J3061). (In addition, check that
24V is output.)
2. Check the connection of the Transfer High Voltage PCB
(J3306).
3. Replace the ETB Unit.
4. Replace the Duplex Driver PCB (PCB4).
Description The leak detection signal was detected 5 times in a row for
every 20 msec.
T-7-4
Summary of Contents for imageRUNNER ADVANCE 6075 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...