
9
9
9-323
9-323
Installation > [TYPE-11] Option HDD (250GB) + Removable HDD Kit + HDD Data Encryption & Mirroring Kit > Installation Procedure > Changing Configuration inside of HDD Case Unit
Installation > [TYPE-11] Option HDD (250GB) + Removable HDD Kit + HDD Data Encryption & Mirroring Kit > Installation Procedure > Changing Configuration inside of HDD Case Unit
11) Remove the HDD Case Unit.
• 2 Screws (The removed screws will be used in “Installing the Encryption Board and HDD
Case Unit” step 3).)
x2
■
Changing Configuration inside of HDD Case Unit
1) Remove the E-ring from the removed HDD Case Unit, remove the shaft of the HDD Cap,
and then remove the HDD Fixed Plate. (The removed HDD Fixed Plate will not be used.)
2) Put the HDD Cap and the shaft back to the HDD Case Unit, and secure the HDD Case Unit
with the E-ring.
F-9-640
F-9-641
3) Remove the Upper Rail from the HDD Case Unit.
• 2 Screws (The removed screws will be used in step 6).)
x2
4) Remove the Leaf Spring from the removed rail in the order of the arrows in the figure
below. (The removed Leaf Spring will not be used.)
• 2 Bosses
• 2 Arms
Boss
Turn over
Boss
Arm
F-9-642
F-9-643
Summary of Contents for imageRUNNER ADVANCE 6075 Series
Page 4: ...Blank Page ...
Page 318: ...3 3 Periodic Service Periodic Service Periodical Service Operation Item ...
Page 565: ...5 5 Adjustment Adjustment Overview When replacing parts ...
Page 686: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 783: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...