Section 8. Working with Data Files on the PC
Stop Offset
This number specifies the number of bytes from the beginning of the file
that Split should stop processing the data file.
In the following figure, Split will skip the first 256 bytes of data before
beginning and stop execution on byte 1024.
Number of Values in Each Burst
When processing a burst data file, enter the total number of values recorded for
each Burst (this is the number of burst scans multiplied by the number of
channels per scan). This number does not include the array ID or calibration
data.
To break the results into a column for each channel, enter the number of
channels for the Break Arrays value (Output File Tab, Other button).
Midnight is 2400 hours
When programming mixed-array dataloggers, the Real Time instruction (P77)
has two different options for the midnight time stamp: midnight = 2400 of the
day just ending or midnight = 0000 of the day just beginning.
When processing mixed-array data files using time synchronization, select this
check box if the time stamp is midnight at 2400 of the day just ending. This
will ensure that Split processes the data file correctly.
Time Offset
This field specifies a time offset, in seconds, that should be applied to each
item on the Select line that uses the Date or Edate function to output a date.
The offset can be positive or negative. Each input file can have its own offset
(or no offset) for its Select line.
8-45
Summary of Contents for LoggerNet
Page 2: ......
Page 30: ...Preface What s New in LoggerNet 4 xxvi...
Page 32: ...Section 1 System Requirements 1 2...
Page 44: ...Section 2 Installation Operation and Backup Procedures 2 12...
Page 136: ...Section 4 Setting up Datalogger Networks 4 80...
Page 227: ...Section 7 Creating and Editing Datalogger Programs 7 9...
Page 298: ...Section 7 Creating and Editing Datalogger Programs 7 80...
Page 402: ...Section 9 Automating Tasks with Task Master 9 12...
Page 406: ...Section 9 Automating Tasks with Task Master 9 16...
Page 450: ...Section 11 Utilities Installed with LoggerNet Admin and LoggerNet Remote 11 22...
Page 454: ...Section 12 Optional Client Applications Available for LoggerNet 12 4...
Page 462: ...Section 13 Implementing Advanced Communications Links 13 8...
Page 482: ...Section 14 Troubleshooting Guide 14 20...
Page 570: ...Appendix F Calibration and Zeroing F 16...
Page 578: ...Appendix G Importing Files into Excel G 8...
Page 579: ......