Chapter 6: Installation Procedures per Configuration Type
2x2 LoS MIMO Direct Mount
phn-3962 004v000
Page 6-57
2x2 LoS MIMO Direct Mount
Figure 26 2x2 LoS MIMO Direct Mount
Note
This procedure can also be used for 1+0 SD configurations
.
List of Items
Table 46 Required items for 2x2 LoS MIMO Direct Mount
Item Description
Quantity
Remarks
1
PTP 820C Radio
1
2
PTP 820C Dual Core Kit
1
3
Flexible WG Kit
1
Optional
4
Coax to WG Kit
1
Optional
Required Tools
•
Metric offset hexagon key set
•
Phillips #1 and #2 screwdriver
Insertion Loss
Table 47 Insertion loss for 2x2 LoS MIMO Direct Mount
Mediation
Devices
Signal
Path/Remarks
Insertion Loss [dB]
6-8 GHz 11 GHz
13-15
GHz
18 GHz
23-26
GHz
28-38
GHz
Dual Core
Mediation
Device and
WG
Radio to antenna
(upper path)
0.2
0.2
0.2
0.3
0.3
0.5
WG port to second
antenna
Frequency band and WG length (antenna separation)
dependent