Chapter 6: Installation Procedures per Configuration Type
2 x MultiCore 2+0 Dual Polarization Remote
Mount
phn-3962 004v000
Page 6-48
Insertion Loss
Table 43 Insertion loss for MultiCore 2+0 Dual Polarization Remote Mount
Mediation
Devices
Signal
Path/Remarks
Insertion Loss [dB]
6-8 GHz 11 GHz
13-15
GHz
18 GHz
23-26
GHz
28-38
GHz
Double
Splitter,
OMT and
two WGs
Radio to antenna
port
4.3
4.3
5
5.2
5.7
6
Common Installation Procedure
142B
1 Prior to the
installation, follow the antenna manufacturer’s instructions to use the circular
adaptor. (Remove the existing rectangular transition, swap the O-ring, and install the circular
transition instead.)
143B
2 Connect the OMT Kit to the antenna and secure it with four screws. Verify the existence of the
O-ring.