Chapter 6: Installation Procedures per Configuration Type
MultiCore 2+2 HSB Single Polarization Remote
Mount
phn-3962 004v000
Page 6-37
Insertion Loss
Table 39 Insertion loss for MultiCore 2+2 HSB Single Polarization Remote Mount
Mediation
Devices
Signal
Path/Remarks
Insertion Loss [dB]
6-8 GHz 11 GHz
1315
GHz
18 GHz
23-26
GHz
28-38
GHz
Splitter and
one WG
Main Paths
5.4
5.4
6.1
6.5
6.8
7.5
Secondary Paths
10
10
10.7
10.9
11.2
11.5
6-13 GHz
126B
1 Mount and tighten the RFU-C Remote Mount Adaptor plate (supplied in RFU-C Adaptor
Remote Mount kit) to the RFU-C Pole Mount using the four flat screws supplied with the RFU-
C Adaptor Remote Mount kit.