T-Modell - 04/05 - Ausgabe 08/04 - 201804286 - BUE-0006-04EN
93
8
Electrical Fittings
Battery alarm for the living area battery
The red ALARM warning light (Fig. 90,13) flashes as soon as the voltage of the living area battery
falls below 11 V (measured under operation) and there is the threat of a total discharge.
Displaying water or waste water volumes
With the V/tank gauge (Fig. 90,1), use the bottom scale. The gauge automatically lights up as soon
as a switch is pressed.
³
Press rocker switch (Fig. 90,12) up
: the volume of water is displayed.
³
Press rocker switch (Fig. 90,12) down
: the volume of waste water is displayed.
8.6.2
Display Digital Clock/Temperature
Switching on digital clock:
³
Press rocker switch (Fig. 90,11) up
: digital clock display is switched on. Temperature
display is ready to operate.
³
Press rocker switch (Fig. 90,11) down
: digital clock display and temperature display are
switched off.
Setting the digital clock:
³
Press a thin device, such as a biro, into the opening for the hour display (Fig. 90,10) until the
correct hours are displayed.
³
Press a thin device, such as a biro, into the opening for the minute display (Fig. 90,9) until the
correct minutes are displayed.
V
When the battery alarm comes on, switch off the appliances and completely charge
the living area battery, either by mobile operation or by connection to a 230 V power
supply.
V
An extended period of total discharge may cause irreparable damage to the living area
battery.
V
If the voltage of the living area battery falls below 10.5 V, the battery monitor switches
off all of the 12 V appliances, excluding the safety/drainage valve.
V
Do not keep the tank levels called up for long. Calling up and displaying for a long time
can damage the transducers.
V
The clock will go on running when the digital clock display is switched off. The actual
time can always be read.
V
The digital clock loses the current time when the living area batteries are disconnect-
ed. When the living area battery is reconnected, the display reads 00:00 and must be
re-set.
Summary of Contents for T-585
Page 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Page 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Page 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Page 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Page 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Page 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Page 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Page 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Page 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Page 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Page 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Page 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Page 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...