9
118
T-Modell - 04/05 - Ausgabe 08/04 - 201804286 - BUE-0006-04EN
Appliances
9.3
Boiler
9.3.1
Trumatic C Boiler
The boiler is integrated in the heater system and operates on gas. It is switched on by turning the
rotary switch (Fig. 116,2) on the operating unit (Fig. 116).
In winter operation "Heater and boiler" (Fig. 116,3) the water is automatically heated up when the
heater is switched on. If the heater switches off after the required room temperature has been
reached the boiler will continue to heat up until the set water temperature has been reached.
In summer operation (Fig. 116,1) only the water in the boiler is heated up to either 40 °C or 60 °C. It
takes approx. 1 hour to heat the water to 60 °C. The yellow indicator lamp (Fig. 116,4) comes on
during the boiler heating-up period.
Winter operation
If the heater is set for winter operation the boiler is already switched on.
Summer operation
Turning on:
³
Open the regulator tap on the gas bottle and
the gas isolator tap "Heater/boiler".
³
Set the rotary switch (Fig. 116,2) on the op-
erating unit (Fig. 116) to "Summer opera-
tion" (Fig. 116,1).
The yellow indicator lamp (Fig. 116,4) is illumi-
nated during the heating up period. When the
set water temperature is reached, the period of
heating up is finished and the yellow indicator
lamp fades.
Turning off:
³
Set the rotary switch (Fig. 116,2) on the op-
erating unit (Fig. 116) to "OFF".
³
Close the regulator tap on the gas bottle
and the gas isolator tap "Heater/boiler".
Fig. 116 Operating unit for heater/boiler
V
Never let gas escape unburned due to danger of explosion.
V
When filling the fuel tank, on ferries or in the garage, the boiler must be turned off.
Danger of explosion!
V
Models with waste gas vent on the right-hand side of the vehicle: if the awning is put
up and the boiler is switched on, exhaust gases from the boiler may build up in the
awning. Danger of suffocation! Make sure the area is sufficiently ventilated.
Summary of Contents for T-585
Page 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Page 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Page 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Page 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Page 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Page 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Page 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Page 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Page 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Page 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Page 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Page 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Page 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...