T-Modell - 04/05 - Ausgabe 08/04 - 201804286 - BUE-0006-04EN
111
9
Appliances
9.2.2
Trumatic C Hot-Air Heater
The hot-air heater has two operating modes:
z
Winter operation
z
Summer operation
Heating is only possible on "Winter" setting. With the "Summer" setting only water in the boiler is
heated. Heating is not possible with this setting.
³
Set the operating mode using the rotary switch (Fig. 106,3):
z
Summer operation "40 °C" or "60 °C" (Fig. 106,2)
z
Winter operation "Heater without Boiler" (Fig. 106,5)
z
Winter operation "Heater and Boiler" (Fig. 106,6)
z
Off (Fig. 106,4)
The hot-air heater cannot be switched off using the 12 V main switch or the rotary knob on the
E-Display.
Winter operation
The heater selects the necessary burner setting
according to the required room temperature.
When the required room temperature is
reached, the burner is switched off. In "Heater
and Boiler" operating mode (Fig. 106,6) water
in the boiler is also heated. In the operating
mode "Heater without Boiler" (Fig. 106,5) the
heater can be operated with an empty boiler.
Turning on:
³
Open the regulator tap on the gas bottle and
the gas isolator tap "Heater/boiler".
³
Turn temperature control knob (Fig. 106,1)
on the operating unit to the required heating
level.
³
Set rotary switch (Fig. 106,3) to winter oper-
ation "Heater without boiler" or to winter op-
eration "Heater and boiler".
Green indicator lamp (Fig. 106,7) comes on.
The circulating fan automatically switches on
when the heater is activated.
Fig. 106 Operating unit for heater/boiler
1
Temperature control knob
2
Summer operation water temperature 40 °C or 60 °C
3
Rotary switch
4
Off
5
Winter operation "Heater without Boiler"
6
Winter operation "Heater and Boiler"
7
Green indicator lamp "Heating operation"
8
Red indicator lamp "Fault"
9
Yellow indicator lamp "Heating-up phase"
V
Empty the heating system when there is a danger of frost the heater is not in opera-
tion.
V
Do not use the space above and behind the Trumatic C hot-air heater for storage.
Summary of Contents for T-585
Page 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Page 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Page 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Page 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Page 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Page 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Page 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Page 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Page 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Page 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Page 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Page 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Page 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...