I. Product Description, Specifications and Dimensional Data
Apex™ Series boilers are condensing high efficiency
gas-fired direct vent hot water boilers
designed for use
in forced hot water space or space heating with indirect
domestic hot water heating systems, where supply water
temperature does not exceed 210°F. These boilers have
special coil type stainless steel heat exchangers, constructed,
tested and stamped per Section IV ‘Heating Boilers’ of
ASME Boiler and Pressure Vessel Code, which provide a
maximum heat transfer and simultaneous protection against
flue gas product corrosion. These boilers are not designed
for use in gravity hot water space heating systems or
systems containing significant amount of dissolved oxygen
(swimming pool water heating, direct domestic hot water
heating, etc.).
Table 1: Dimensional Data (See Figures 1a, 1B and 1C)
Dimension
Boiler Model
aPX399
aPX500
aPX800
A - Inch
(mm)
28-7/8
(734)
44-7/8
(1140)
54-9/16
(1384)
B - Inch
(mm)
6-3/16
(157)
22-1/8
(562)
28-3/8
(724)
C - Inch
(mm)
13-1/16
(332)
29
(737)
34-1/4
(876)
D - Inch
(mm)
23-3/4
(602)
39-11/16
(1008)
48-1/16
(1226)
E - Inch
(mm)
15-13/16
(402)
29-3/8
(752)
33-13/16
(864)
Gas Inlet F
(FPT)
3/4”
3/4”
1
Return G
1-1/2” (FPT)
2” (MPT)
Supply H
1-1/2” (FPT)
2” (MPT)
Condensate Drain J
Factory Provided Socket End Compression Pipe Joining Clamp for 3/4” Schedule 40 PVC Pipe
Boiler Two-Pipe
CPVC/PVC Vent Connector
(Figures 1A, 1B and 1C) - Inch
4 x 4
6 x 6
Approx. Shipping Weight (LBS)
304
350
430
Summary of Contents for Apex APX399
Page 65: ...65 VIII Electrical continued Figure 43 Ladder Diagram ...
Page 66: ...66 VIII Electrical continued ...
Page 67: ...67 Figure 44 Wiring Connections Diagram VIII Electrical continued ...
Page 110: ...110 1P 3 1P 2 1P 1 XIII Repair Parts continued 1C 1D 1E ...
Page 116: ...116 XIII Repair Parts continued ...
Page 118: ...118 XIII Repair Parts continued ...
Page 129: ...129 SERVICE RECORD DATE SERVICE PERFORMED ...
Page 130: ...130 SERVICE RECORD DATE SERVICE PERFORMED ...