Type 8756
Technical data
english
22
▪
the flow-rate value
▪
the size of the product fluid connections
▪
the type of the product fluid connections
▪
the size of the product base block
▪
the type of operating fluid
The following figure gives the pressure loss for water through an
MFM.
0,00
1,00
2,00
3,00
4,00
5,00
6,00
7,00
8,00
9,00
10,00
11,00
12,00
13,00
14,00
15,00
16,00
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1mPas
5mPas
10mPas
25mPas
50mPas
100mPas
150mPas
200mPas
[kg/h]
∆p [bar]
Nominal flow rate Q
Fig. 9: Pressure loss diagram, MFM
4.5.3
Mass Flow Controller with pump
Operating fluid
Liquids
Type of liquids
Liquids that are clean and ho-
mogeneous
Maximum particle size
10 μm
Minimum dynamic viscosity
0.3 mPa.s
Maximum dynamic viscosity
200 mPa.s, with reduced flow-
rate range. If the flow rate is
equal to 8 kg/h, then the fluid
viscosity must be max.
50 mPa.s.
Take the pressure loss into ac-
count. Refer to chapter:
Tab. 14: Operating fluid
Temperature range
–10...60 °C
Measurement accuracy for
mass flow rate values higher
than 1.5 kg/h
±1.0 °C
Repeatability for mass flow rate
values higher than 1.5 kg/h
±0.5 °C
Tab. 15: Temperature measurement
Mass flow rate range
0.05...8 kg/h