Type 8756
Technical data
english
20
Product part
Material
Parts in contact
with the fluid (MFC
with proportional
valve)
Stainless steel 303, stainless steel 434, stain-
less steel 301
The material depends on the equipped pro-
portional valve
Tab. 8: Product materials
4.4
Dimensions, weight
Refer to the data sheet of the related product.
4.5
Fluid data
4.5.1
Mass Flow Meter
Calibration fluid
Water
Temperature of the calibration
fluid
25 °C
Calibration pressure
4 bar
Tab. 9: Calibration conditions
Operating fluid
Liquids
Type of liquids
Liquids that are clean and ho-
mogeneous
Maximum particle size
10 μm
Minimum dynamic viscosity
0.3 mPa.s
Maximum dynamic viscosity
200 mPa.s
Take the pressure loss into ac-
count. Refer to chapter:
Tab. 10: Operating fluid
Density range
0...5 kg/l
Measurement accuracy for
mass flow rate values higher
than 1.5 kg/h
±0.01 kg/l
Repeatability for mass flow rate
values higher than 1.5 kg/h
±0.005 kg/l
Tab. 11: Density measurement
Temperature range
–10...70 °C
Measurement accuracy for
mass flow rate values higher
than 1.5 kg/h
±1.0 °C
Repeatability for mass flow rate
values higher than 1.5 kg/h
±0.5 °C
Tab. 12: Temperature measurement
Mass flow rate range
0.05...25 kg/h
Measurement accuracy after
1 minute warm-up time
±0.2% of the measured value
PLUS ±0.0014 kg/h.
0.0014 kg/h = zero-point stabil-
ity