
2006 Buell Ulysses: Electrical
7-13
HOME
STARTER INTERLOCK
7.5
GENERAL
The starter interlock system is designed to prevent unin-
tended start-up.
Two circuits make up the starter interlock system.
Starter Circuit
The starter circuit prevents the motorcycle from being started
unless a ground has been established at the starter relay.
This ground may come from one of two sources.
●
By placing the motorcycle in neutral and grounding
through the neutral switch.
●
By disengaging the clutch and grounding through the
clutch lever switch.
Once the starter circuit is grounded and the starter button
pushed, the starter relay can be energized. The energized
relay then permits the starter motor to crank the engine.
Table 7-11. Starter Interlock Troubleshooting
PROBLEM
CHECK FOR
CORRECTION
Electric starter will not crank.
Battery problems.
See
7.11 BATTERY
.
Inappropriate gear selected.
Place vehicle in neutral.
Clutch lever not disengaged.
Pull in clutch lever.
Starter relay problems.
Listen for starter relay “click”. If click is not heard,
perform starter relay tests.
Follow starter troubleshooting in Section 5.
Summary of Contents for Ulysses 2006
Page 2: ......
Page 12: ...HOME ...
Page 46: ...D 2 2006 Buell Ulysses Appendix D HOME Figure D 2 Rear Brake Systems Top View b1115acsxu ...
Page 58: ...HOME NOTES ...
Page 68: ......
Page 98: ...HOME NOTES ...
Page 124: ......
Page 232: ...HOME NOTES ...
Page 234: ......
Page 340: ...HOME NOTES ...
Page 344: ...HOME NOTES ...
Page 384: ...HOME NOTES ...
Page 472: ...HOME NOTES ...
Page 474: ......
Page 498: ......
Page 554: ......
Page 578: ...HOME NOTES ...
Page 638: ......