TROUBLE CODE 44
4.27
GENERAL
NOTE
See
Figure 4-57.
When vehicle lean angle causes weighted
pendulum to enter shaded area for a period of greater than
one second, ECM shuts off ignition and fuel systems.
Bank Angle Sensor
See
Figure 4-58.
A Code 44 occurs when the bank angle
sensor voltage is outside the normal operating range of 0.25-
2.7 volts. Refer to
Table 4-31.
This may be caused by:
●
Short to ground in harness between sensor and elec-
tronic control module.
●
Short to voltage in harness between sensor and elec-
tronic control module.
●
Failed sensor.
If this code occurs, the engine may stop running. The engine
may still be restarted and ridden to the dealership for repair.
DIAGNOSTICS
Diagnostic Notes
The reference numbers below correlate with the circled num-
bers on the Code 44 flow charts.
1.
Use HARNESS CONNECTOR TEST KIT (Part No. HD-
41404), gray pin probes and patch cord.
2.
Connect BREAKOUT BOX (Part No. HD-42682) to ECM.
See
4.6 BREAKOUT BOX
.
Figure 4-57. Bank Angle Sensor Operation
Table 4-31. Bank Angle Sensor Voltage
MODE
VOLTS
Run mode
0.25-2.7
Disable mode
2.8-4.8
Figure 4-58. Bank Angle Sensor (Under ECM)
b1085x4x
Run Mode 0.25-2.7 volts
Disable Mode 2.8-4.8 volts
Weighted pendulum
11968
Summary of Contents for Ulysses 2006
Page 2: ......
Page 12: ...HOME ...
Page 46: ...D 2 2006 Buell Ulysses Appendix D HOME Figure D 2 Rear Brake Systems Top View b1115acsxu ...
Page 58: ...HOME NOTES ...
Page 68: ......
Page 98: ...HOME NOTES ...
Page 124: ......
Page 232: ...HOME NOTES ...
Page 234: ......
Page 340: ...HOME NOTES ...
Page 344: ...HOME NOTES ...
Page 384: ...HOME NOTES ...
Page 472: ...HOME NOTES ...
Page 474: ......
Page 498: ......
Page 554: ......
Page 578: ...HOME NOTES ...
Page 638: ......