![Buderus Logamatic 4323 Service Instructions Manual Download Page 72](http://html.mh-extra.com/html/buderus/logamatic-4323/logamatic-4323_service-instructions-manual_2826358072.webp)
Heating circuit data
11
Logamatic 4323 - Subject to technical modifications.
72
Heat-up time
By setting the "Increase" parameter, you determine in which daily cycle
the temperature should rise to dry out the screed.
Turn the rotary selector until submenu "Screed drying Increase" appears.
The display shows the selected submenu.
Hold down "Display" and turn the rotary selector until the required value appears
(here: "every 5th day").
The display shows the set value.
Release "Display" to save your input.
Setting the maximum temperature
Here you may enter the maximum temperature for screed drying.
Turn the rotary selector until submenu "Screed drying Max. temperature"
appears.
The display shows the selected submenu.
Hold down "Display" and turn the rotary selector until the required value appears
(here: "25°C").
The display shows the set value.
Release "Display" to save your input.
HEAT CIRC. DATA 2
every day
Increase
Screed drying
+
HEAT CIRC. DATA 2
every 5th day
Increase
Screed drying
Input range
Factory setting
Increase in daily cycles
every day – every 5th day
every day
HEAT CIRC. DATA 2
45°C
Max. temperature
Screed drying
+
HEAT CIRC. DATA 2
25°C
Max. temperature
Screed drying
Input range
Factory setting
Maximum temperature
25 °C – 60 °C
45 °C