Heating circuit data
11
Logamatic 4323 - Subject to technical modifications.
57
11.14 Room temperature offset
This setting is only recommended if no remote control has been installed inside
the living space.
If the average actual temperature measured with a thermometer deviates from the
set temperature for some time, this function enables a matching of both values.
Parallel offset of the heating curve through matching.
The changes take effect after a time delay.
Example:
The set value lies 2
°C below the actual value.
Call up the service level. "Gen. parameters" is shown as the first main menu.
Turn the rotary selector until the main menu "Heating circ. + no." appears
(here: "Heating circ. 2").
Press "Display" to call up a submenu (here: "Heating system").
The display shows the selected submenu.
Turn the rotary selector until submenu "Room temperature Offset" appears.
The display shows the selected submenu.
Hold down "Display" and turn the rotary selector until the required value appears
(here: "-2°C").
The display shows the set value.
Release "Display" to save your input.
Press "Back" to return to the next level up.
Displayed set room temperature
22
°C
Actual room temperature
24
°C
+
+
HEAT CIRC. DATA 2
Radiators
Heating system
HEAT CIRC. DATA 2
0°C
Offset
Room temperature
+
HEAT CIRC. DATA 2
-2°C
Offset
Room temperature
Input range
Factory setting
Offset
-5 °C – 5 °C
0 °C