TROUBLESHOOTING
TROUBLESHOOTING
Check circuit breaker. Reset if necessary.
Check battery connections.
Check footrest safety switches to see if one of these limit
switches is depressed. Sliding safety tray below footrest should
slide freely and should not stick in a position which would
depress one of the safety switches.
Check for discharged batteries. Battery voltage should be in a
range of 16-28 VDC.
Commercial units only
: Check fuse. Replace if necessary.
Check for discharged batteries.
Check setting of speed control potentiometer.
Check for loose connections.
Check to make sure charger is plugged in and working.
Unit has been connected for left-hand operation but is installed
on the right-hand side of the stairs (or vice versa).
Make correct connections according to instructions in the
installation manual, section on
Reversing Operations.
UNIT FAILS TO
OPERATE
UNIT OPERATES
SLOWLY, LACKS
POWER
CONTROLS OPERATE
BACKWARDS AND UNIT
GOES "UP" SLOWLY AND
"DOWN" FAST