© 2004,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
37
SRE-1540 UL 06-18-2004
As shipped from the factory, the Elevator is set up for left-hand installation (as viewed from the bottom of
the stairs.) Should the installation require a right-hand installation, perform the following operations:
1. Turn the on / off circuit breaker on the rear of carriage to `OFF'.
2. Remove left carriage cover.
3. Set the Installation DIP Switch (S2) to the `RH' position.
4. Set the No. 1 DIP Switch on the 4-Ganged Dip Switch (S1) to the `OFF' position.
5. Check that the power Switch (S3) is turned `ON' .
6. Unplug the motor leads and reverse the connections.
7. Turn the circuit breaker switch to the “ON” position.
8. Replace the carriage cover.
CHANGING CONTROLS FROM RIGHT TO LEFT ARMREST
SET THE
INSTALLATION DIP
SWITCH (S2) FROM
`LH' TO `RH'
POSITION
SET NO. 1 SWITCH
OF (S1)
TO THE `OFF'
POSITION
POWER DIP
SWITCH (S3)
REVERSING CONNECTIONS
CIRCUIT BOARD
INSTALLATION
INSTALLATION
1. Remove the switch housing weldment by removing the Torx head machine screw
under the arm.
2. Carefully pry the rocker switch out of the switch housing weldment.
3. Make note of wire locations, then disconnect the harness.
4. Remove the bushing from the seat frame weldment under the arm.
5. Remove the second bushing from the center of the seat frame weldment under the seat.
6. Remove dome cap plug.
7. Feed the harness to the left arm.
8. Reconnect wires as they were on the right side.
9. Replace the bushings.
10. Insert the dome cap plug in the hole under the right arm rest.
CONVERSION TO RIGHT-HAND INSTALLATION -
COMMERCIAL UNIT