© 2004,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-1540 UL 06-18-2004
36
AUDIO REFERENCE
INSTALLATION
INSTALLATION
Chirp
.25 Seconds
Short Beep
.5 Seconds
Long Beep
1.5 Seconds
Pause
1 Second
CHANGING THE PCB DIAGNOSTIC MODE
* Turn the Circuit Breaker on the carriage to `OFF'.
* Remove Left carriage cover.
* Turn the Power DIP Switch (SW3) to the `OFF' position.
* Unit is shipped is Multi-User Diagnostic Mode.
Changes are made on (S1) 4 Ganged DIP Switch -
Number 3 and Number 4 Positions.
4 GANGED DIP SWITCH (SW1)
DIAGNOSTIC MODE
DIP SWITCH POSITION
#3
#4
Multi-User
OFF
OFF
Single-User
OFF
ON
Quiet
ON
OFF
Battery Warning Only
ON
ON
OTHER CIRCUIT BOARD FEATURES
CIRCUIT BOARD DIAGNOSTICS
COMMERCIAL UNIT
NOTICE:
Before touching anything inside the carriage assembly,
ground yourself by touching an unpainted metal
surface on the unit such as an exposed bolt,
or one of the mounting screws on the electrical panel.
While you work, periodically touch an unpainted metal
surface to dissipate any static electricity that could
harm internal components.
Also located on S1 DIP Switch are switch #1 Installation and #2 Coast Delay. Refer to Re-
versing Operation instructions for changing Switch # 1. The coast delay option (Switch #2 on
S1) has been provided in cases of interference which may cause intermittent operation. The
normal setting is 600 mS seconds of coast, should the unit lose the remote call/send signal,
this can be increased to 900mS seconds by moving switch # 2 on S1 to the `ON' position.