© 2004,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-1540 UL 06-18-2004
38
TRAIN THE CUSTOMER TO USE THE STAIRWAY
ELEVATOR CORRECTLY AND SAFELY. BE SURE TO
HAVE THE CUSTOMER OPERATE THE UNIT WHILE
YOU ARE THERE TO ANSWER ANY QUESTIONS OR
CONCERNS. REMIND THE CUSTOMER TO ALWAYS USE
THE SEAT BELT.
A slight delay will occur between the time the rocker switch is depressed and the initiation
of carriage movement. This is normal and is a function of the
soft start
feature of the
controller
.
♦
Run the unit up and down the stairs using the rocker switch on the carriage. The
unit should operate in such a way that the arrow depressed on the rocker switch
corresponds to the desired direction of travel.
The unit should travel noticeably faster going up than down.
♦
Run the unit up and down the stairs using the remote call/send transmitters. Test
both transmitters.
♦
Push the seat into the stored position and run the unit up and down the stairs with the
remote call/send transmitter.
♦
With the seat in the central riding position, move the Elevator completely down and up
the rail, while observing the elevator-to-wall clearance. A clearance of 1/2" to 1" is
acceptable. Repeat the run with the seat in the folded position. If necessary, adjust
the rail placement by sliding it closer to, or further from the wall.
♦
Verify proper operation of the following: speed, direction, final limit switch, footrest
safety switch, seat swivel safety switch, and remote call/send transmitter.
Testing the Call/Send Transmitters
INSTALLATION