[ ] Remove seat
[ ] Remove carriage from rail.
[ ] To adjust limit switches remove covers and rotate angle adjustment bracket
weldment, if necessary, to access the limit switches.
[ ] Loosen limit switches using a 9/16" box wrench on the outside nut and a 5/8" open end
wrench on the inside nut. It may also be necessary to use a pair of needle nose pliers.
To access the limit switch on the motor side, it may be necessary to remove the charge
contact assembly. Remove wire tie on the charge contact. Slide it out of the way, being
careful to keep wires connected. Remove the outer nut on limit switch and slide limit
switch out so that the inside nut can be adjusted. Tighten and reinstall parts. Replace
covers and adjust the angle adjustment bracket. Replace unit on rail and perform a
test to make sure unit will charge correctly.