© 2004,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
19
SRE-1540 UL 06-18-2004
[ ] Adjust the carriage angle by loosening the angle adjustment bolts. Level the angle
adjustment aracket, using a standard builder's level or protractor level. When the
angle adjustment bracket is level, securely tighten all four angle adjustment bolts*.
TORQUE RATING = 70 LB-FT
angle adjustment
bracket
(For a more
detailed
view of
safety lock
washer
inserted
with lower
bolt, see
CARRIAGE
ASSEMBLY
DRAWING,
SRE-00060,
at the back
of this
manual.)
REMINDER:
Recheck with level after tightening
adjustment bolts.
[ ] Turn toggle switch off. When facing the front of the unit, remove the left motor
cover. Slide the carriage into the rail until the spur gear rests on the gear rack.
Manually turn the motor pulley to fully engage the entire carriage inside the
upper rail.
INSTALLATION
call/send
antenna
(commercial units only)
INSTALLATION
MOUNTING CARRIAGE ON UPPER RAIL - Residential and Commercial Units
ADJUSTING THE CARRIAGE ANGLE
angle adjustment
bolts