275
Troubleshooting
(7)
Remove the filter from the bracket.
X0397
(8)
Rotate the nut of the tube on the head side and remove the filter.
X0437
(9)
Place a new filter on the head side tube and fasten the nut.
<IMPORTANT>
Install the filter with no stamp facing the tube. Pay attention to this installation orientation.
<NOTE>
For a proper work operation, be sure to wear the printer-provided gloves.
X0334
Nut
New filter
Without stamp
Head side tube
Nut
Filter
Filter
Bracket