3-96
Confidential
(5) Release the High-voltage power supply flat cable from the securing fixtures inside the
machine and extend the folds. Remove the two Taptite bind B M4x12 screws. Release
each Hook to remove the High-voltage power supply PCB. Disconnect the HVPS
harness, the Develop release sensor harness, and the Fan harness from the High-voltage
power supply PCB. Disconnect the High-voltage power supply flat cable from the High-
voltage power supply PCB.
(6) Release the Hook to remove the Develop release sensor PCB.
Fig. 3-84
Harness routing: Refer to
“11. High-voltage power supply PCB, Fan harness, LED ground
wire”
.
Assembling Note:
• After attaching the High-voltage power supply PCB, check whether the Electrodes inside
the machine are not dropping or not get caught by pushing the Electrodes inside the
machine.
• When connecting the High-voltage power supply flat cable, pull out the High-voltage
power supply flat cable from the machine and then connect it to the High-voltage power
supply PCB. Then, attach the High-voltage power supply PCB to the machine while
pulling the High-voltage power supply flat cable to the machine side (Refer to
voltage power supply flat cable”
.)
Hooks
Hooks
Hooks
High-voltage power supply PCB
Taptite bind
B M4x12
Hooks
Develop release
sensor PCB
Hook
Fan harness
Develop release
sensor harness
HVPS harness
High-voltage
power supply
flat cable
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...