Error code EC00
Overcurrent was caused because a USB device that did not meet the specifications was
inserted into the USB port.
<User Check>
• Disconnect the USB device from the USB flash memory port and turn the machine OFF.
Turn the machine ON again after a while.
• Replace the USB device with a different one.
■
Error code F900
The spec code was not entered correctly.
Step
Cause
Remedy
1
USB host PCB failure
Replace the USB host PCB.
2
Main PCB failure
Replace the main PCB.
Step
Cause
Remedy
1
The power was turned OFF while
function code 74 was running.
Reenter the spec code. (Refer to
Configure for country/region and model
(Function code 74)” in Chapter 5
2
Main PCB failure
Replace the main PCB.