2-148
Confidential
■
Faulty registration
• First side (Document scanner unit)
• Second side (ADF unit)
■
Dark
Step
Cause
Remedy
1
Deviation of the scanning
start position
Execute “Fine adjustment of scan start
position (
)”.
2
Document scanning position
actuator caught in some
sections of the machine
Reattach the document scanning position
actuator.
Step
Cause
Remedy
1
Deviation of the scanning
start position
Execute “Fine adjustment of scan start
position (
)”.
2
Document scanning position
actuator caught in some
sections of the machine
Reattach the document scanning position
actuator.
<User Check>
• Check that the contrast setting is not too dark.
• Clean the first side/second side document hold.
Step
Cause
Remedy
1
Incorrect white level
correction data
Execute “Acquire white level data (
)”.
2
First or second side CIS unit
failure
Replace the first or second side CIS unit.
3
Main PCB failure
Replace the main PCB.