2-141
Confidential
4.7.4 Drum error
<User Check>
• Clean the corona wire of the drum unit.
• Replace the drum unit with a new one.
4.7.5 Drum replacement message displayed on LCD is not cleared
<User Check>
• Reset the drum counter according to the manual.
Step
Cause
Remedy
1
Dirt on the electrodes of the
drum unit and those of the
machine
Clean the electrodes of the drum unit and
those of the machine. (Refer to
and
2
Dirt on the electrodes of the
high-voltage power supply
PCB and those of the
machine
Clean the electrodes of the high-voltage
power supply PCB and those of the machine.
3
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB.
4
Main PCB failure
Replace the main PCB.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB.
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...