![Brother DCP-L3510CDW Service Manual Download Page 57](http://html.mh-extra.com/html/brother/dcp-l3510cdw/dcp-l3510cdw_service-manual_53471057.webp)
2-21
Confidential
Error
Codes
Description
Refer
to:
Error
Codes
Description
Refer
to:
6004
The eject sensor detected that the
fuser cover was open.
6602
6007
6701
6101
Developing terminal voltage detected
that the toner cartridge (black) was
not installed.
6801
The internal temperature sensor
detected a temperature higher than
the specified value.
6102
Developing terminal voltage detected
that the toner cartridge (yellow) was
not installed.
6802
6103
Developing terminal voltage detected
that the toner cartridge (magenta) was
not installed.
6901
Some fuser unit errors occurred at
power-ON or upon recovery from
sleep mode.
6104
Developing terminal voltage detected
that the toner cartridge (cyan) was not
installed.
6902
After the error was detected at the
fuser unit, power was turned ON
again and the error is being checked.
(If power is turned OFF and ON after
error code 6901 occurred, this code is
displayed for about 15 minutes.)
6106
6A00
Electric discharge that may be caused
by dirt on the corona wire of the drum
unit was detected.
6200
6B01
Electric discharge was detected when
the number of the black drum unit
rotations had become more than twice
of the upper limit.
6201
GRID terminal signal detected that the
black drum unit was not installed.
6B02
Electric discharge was detected when
the number of the yellow drum unit
rotations had become more than twice
of the upper limit.
6202
GRID terminal signal detected that the
yellow drum unit was not installed.
6B03
Electric discharge was detected when
the number of the magenta drum unit
rotations had become more than twice
of the upper limit.
6203
GRID terminal signal detected that the
magenta drum unit was not installed.
6B04
Electric discharge was detected when
the number of the cyan drum unit
rotations had become more than twice
of the upper limit.
6204
GRID terminal signal detected that the
cyan drum unit was not installed.
6B0A
6208
6C01
6209
6C02
620A
Electrified terminal or GRID terminal
signal detected that the black drum
was not installed when the machine
was turned ON.
6C03
620B
Electrified terminal or GRID terminal
signal detected that the yellow drum
was not installed when the machine
was turned ON.
6C04
620C
Electrified terminal or GRID terminal
signal detected that the magenta
drum was not installed when the
machine was turned ON.
6D00
620D
Electrified terminal or GRID terminal
signal detected that the cyan drum
was not installed when the machine
was turned ON.
6E00
The develop release sensor detected
the develop roller disengagement or
engagement failure.
6300
The electrodes of the high-voltage
power supply PCB detected that no
waste toner box was set.
6F00
Detected that supply power is
unstable (less than 100 times).
6400
The registration mark sensor detected
that no belt unit was set.
7000
After the registration rear sensor
detects paper pass, the eject sensor
does not detect paper pass.
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...