2-142
Confidential
4.8 Troubleshooting for Fuser Unit Problems
4.8.1 Fuser unit failure
4.9 Troubleshooting for LED ASSY Problems
4.9.1 LED ASSY failure
<User Check>
• Turn ON the power switch, then open the top cover and the back cover. Leave the machine
for a while to remove condensation.
Step
Cause
Remedy
1
Connection failure of the
center thermistor harness
Reconnect the center thermistor harness.
2
Connection failure of the side
thermistor harness
Reconnect the side thermistor harness.
3
Connection failure of the
heater harness
Reconnect the heater harness.
4
Connection failure of the eject
sensor harness
Reconnect the eject sensor harness.
5
Eject sensor PCB failure
Replace the eject sensor PCB.
6
Low-voltage power supply
PCB failure
Replace the low-voltage power supply PCB.
7
Fuser unit failure
Replace the fuser unit.
8
Main PCB failure
Replace the main PCB.
Note:
• Turn the power switch OFF and then ON again. Leave the machine for 15 minutes.
This problem may then be cleared.
• The machine may recover from the error, when the test printing of the maintenance mode
for service personnel is started. However, conducting this operation while the heater has
not yet cooled may cause the fuser unit to melt. Be careful.
Step
Cause
Remedy
1
LED ASSY attachment failure
Reattach an LED ASSY.
2
Connection failure of the LED
ASSY flat cable
Reconnect an LED ASSY flat cable.
3
Connection failure of the LED
control flat cable
Reconnect the LED control flat cable.
4
LED ASSY flat cable failure
Replace an LED ASSY flat cable.
5
LED control flat cable failure
Replace the LED control flat cable.
6
LED control PCB failure
Replace the LED control PCB.
7
LED ASSY failure
Replace an LED ASSY.
8
Main PCB failure
Replace the main PCB.
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...