2-125
Confidential
■
Vertical streaks in a dark background
<User Check>
• Clean the corona wire of the drum unit.
• This problem may disappear after printing multiple sheets of paper.
• Refer to
to remove the dirt from the exposure drum using a
cotton applicator.
• Turn ON the power switch, and leave the machine for a while.
• Wipe the LED ASSY with a soft, lint-free cloth. (Refer to
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
■
Horizontal stripes
Step
Cause
Remedy
1
Dirty charge electrodes
Clean the electrodes of the drum unit and
those of the machine. (Refer to
2
LED ASSY failure
Replace the appropriate LED ASSY.
<User Check>
• Clean the corona wire of the drum unit.
• This problem may disappear after printing multiple sheets of paper.
• Refer to
to remove the dirt from the
exposure drum using a cotton applicator.
• Replace the drum unit with a new one.
• Replace the toner cartridge with a new one.
Step
Cause
Remedy
1
Dirty charge electrodes
Clean the electrodes of the drum unit and
those of the machine. (Refer to
and
.)
2
A ground wire or ground plate
installation failure (Grounding
is not performed correctly.)
Retighten the screws of each ground wire or
ground plate. Repair the bend of the tray
ground spring of the T1.
(Refer to
3
Scratch or dirt on the fuser unit
Replace the fuser unit.
4
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB.
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...