Error code C700
The memory is insufficient to expand the data of PC-Print.
Error code C800
The memory used to store secure print data exceeded the memory size for secure print data.
Error code C900
Storage memory was full and data could not be saved.
<User Check>
• Print the print data stored in the memory.
• Divide the print data and print them separately.
• Organize data inside the storage memory.
■
Error code D100
An error occurred while initializing the modem.
Error code D200
Detected that the modem PCB is not connected.
■
Error code D800
An error occurred while initializing the touch panel.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB.
Step
Cause
Remedy
1
Connection failure of the modem
flat cable
Reconnect the modem flat cable.
2
Modem flat cable failure
Replace the modem flat cable.
3
Modem PCB failure
Replace the modem PCB.
4
Main PCB failure
Replace the main PCB.
Step
Cause
Remedy
1
Connection failure of the panel
flat cable
Reconnect the panel flat cable.
2
Touch panel ASSY failure
Replace the touch panel ASSY.
3
Panel PCB failure
Replace the panel PCB.
4
Main PCB failure
Replace the main PCB.
Summary of Contents for DCP-L3510CDW
Page 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Page 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Page 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Page 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Page 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Page 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...