Confidential
App. 1-24
< WSW19 >
Selector No.
Function
Setting and Specifications
1
|
3
First transmission speed choice
for fallback
4
|
6
Last transmission speed choice
for fallback
No. 1 2 3
No. 4 5 6
0 0 0: 2,400 bps
0 0 1: 4,800 bps
0 1 0: 7,200 bps
0 1 1: 9,600 bps
1 0 0: 12,000 bps
1 0 1: 14,400 bps
1 1 0: 14,400 bps
1 1 1: 14,400 bps
7
V.34 mode (Not used.)
0: Permitted
1: Prohibited
8
V.17 mode
0: Permitted
1: Prohibited
Note:
Selector 7 takes effect only in models supporting V.34 mode.
- Selectors 1 through 6: First and last choices of transmission speed for fallback
These selectors are used to set the MODEM speed range. With the first transmission
speed choice specified by selectors 1 through 3, the machine attempts to establish the
transmission link via the MODEM. If the establishment fails, the machine automatically
steps down to the next lowest speed and attempts to establish the transmission link again.
The machine repeats this sequence while stepping down the transmission speed to the
last choice specified by selectors 4 through 6.
If the MODEM always falls back to a low transmission speed (e.g., 4,800 bps), set the first
transmission speed choice to the lower one (e.g., modify it from 12,000 bps to 7,200 bps)
in order to deactivate the high-speed MODEM function and reduce the training time for
shorter transmission time.
Generally, to save the transmission time, set the last transmission speed choice to a
higher one.
- Selector 7: V.34 mode (Not used.)
If this selector is set to “0,” selectors 5 through 8 on the WSW38 through WSW40 and on
WSW41, will become effective.
Summary of Contents for DCP-9045CDN
Page 239: ...Confidential 3 106 11 Remove the LCD from the Backlight module Fig 3 129 LCD Backlight module ...
Page 349: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 365: ...Confidential 5 5 Black and white level data for scanning compensation Fig 5 1 ...
Page 382: ...Confidential 5 22 Cover page sample Fig 5 12 End page sample Fig 5 13 ...
Page 405: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 406: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 407: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 408: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 409: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 410: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 411: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 413: ...Confidential 6 10 Filter PCB Circuit Diagram ...