Confidential
3-151
8.37 Engine PCB ASSY
(1) Disconnect all the connectors from the Engine PCB ASSY.
Note:
- After disconnecting the flat cable(s), check that each cable is not damaged at its end or
short-circuited.
- When connecting the flat cable(s), do not insert it at an angle. After insertion, check that
the cable is not at an angle.
CN29
CN31
CN32
CN30
CN33
CN35
CN34
CN38
CN40
CN42
CN41
CN43
CN39
CN36
CN37
CN28
CN27
CN26
CN25
CN24
CN23
CN22
CN21
CN19
CN18
CN20
CN17
CN16
CN15
CN14
CN13
CN12
CN11
CN6
CN10
CN5
CN1
CN2
CN3
CN4
CN7
CN8
CN9
Fig. 3-212
(2) Remove the five cup S M3x6 Taptite screws, and then remove the Engine PCB ASSY from
the Frame unit.
Fig. 3-213
Engine PCB ASSY
Taptite, cup S M3x6
Engine PCB ASSY
Frame unit
Summary of Contents for DCP-9045CDN
Page 239: ...Confidential 3 106 11 Remove the LCD from the Backlight module Fig 3 129 LCD Backlight module ...
Page 349: ...Confidential 4 5 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 365: ...Confidential 5 5 Black and white level data for scanning compensation Fig 5 1 ...
Page 382: ...Confidential 5 22 Cover page sample Fig 5 12 End page sample Fig 5 13 ...
Page 405: ...Confidential 6 2 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 406: ...Confidential 6 3 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 407: ...Confidential 6 4 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 408: ...Confidential 6 5 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 409: ...Confidential 6 6 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 410: ...Confidential 6 7 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 411: ...Confidential 6 8 Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 413: ...Confidential 6 10 Filter PCB Circuit Diagram ...