5. Log back in to the standby CP blade and run
firmwareDownloadStatus
on the standby CP blade
to validate a successful commit. This may take 10 minutes.
6. If you are upgrading through several levels of the Fabric OS, repeat step 2 through step 5 as often
as necessary based on the path outlined in the preceding table. Otherwise, proceed to step 7.
7. Log out of the standby CP blade and log in to the active CP blade.
8. Proceed to
on page 91.
Downloading firmware from a USB device
For this task, refer to
Verifying operation of the new CP blade
on page 88 for the correct sequence of
upgrading firmware versions to reach your target version.
Complete the following steps to download the firmware from a USB device.
This section assumes that the new firmware has already been copied onto the USB device. The folder
structure on the USB device must be as follows in order to allow the device to be enabled:
• brocade>
‐
config
‐
firmware
‐
firmwareKey
‐
support
The firmware folder contains the folder for the specific release you are installing.
1. Insert the USB device into the active CP blade.
2. Attach a serial cable from the PC to the active CP blade.
3. Log in to the active CP blade as
admin
if you are not still logged in and enter
usbStorage -e
to
enable the USB device.
4. Remove the serial cable from the active CP blade and attach it to the standby CP blade and log in
as
admin
.
5. Run
firmwareDownload -s
to download the firmware to the standby CP blade. The
-s
option also
disables the autoreboot, so you will have to manually issue a reboot after the download finishes to
initiate
firmwarecommit
. Enter all requested information (use default values).
6. This does not apply to the DCX 8510 models. When the download process finishes, run
firmwareDownloadStatus
to verify that the firmware has been updated. The command displays a
running account of the progress of the
firmwareDownload
command until the command has
completed. The final message is similar to the following and will appear with a date and time stamp:
Slot 6 (CP0, active): Firmwaredownload command has completed successfully. Use
firmwareshow to verify the firmware versions.
7. Ensure that you are still logged in to the standby CP blade (the blade for which you just changed
the firmware level) and type
reboot
. The reboot of the standby CP will initiate a
firmwarecommit
to
the secondary partition and log you out.
DCX_124:admin> reboot
Broadcast message from root (ttyS0) Fri Jun 18 14:49:45 2010...
The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal DCX_124:admin> HAMu Heartbeat down, stop
FSS
Unmounting all f##exiting due to signal: 9, pending signals: 0x20000, 0x0
ilesystems.
Please stand by while rebooting the system...
Restarting system.
The system is coming up, please wait...
.
.
.
Fri Jun 18 14:53:13 2010: Doing firmwarecommit now.
Please wait ...
Downloading firmware from a USB device
90
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-08
Summary of Contents for DCX 8510-8
Page 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Page 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...