Troubleshooting the Brocade DCX 8510-8 (Continued)
TABLE 18
Issue
Possible cause
Recommended action
Blades might be faulty.
Enter the
slotShow
command to determine status.
For more information, enter the
diagDisablePost
command; then, use the
slotPowerOff
[
slot number
]
and
slotPowerOn
[
slot number
] command. Resolve
the source of the problem or replace the blade as
required.
Pins on the blade or the
backplane might be
damaged.
Remove the blade from the chassis and inspect the
pins on the blade and on the backplane inside the
slot. Do not reinstall if the pins on either component
are damaged, as this could damage pins on other
components. Replace the components as required.
An individual component is not
operating as expected.
Component may not have
power or may not be firmly
seated.
Ensure that the component is receiving power
(power LED should be on) and the component is
firmly seated.
Pins on the component or
the backplane might be
damaged.
Remove the component from the chassis and
inspect the pins on the blade and inside the chassis.
Do not reinstall if the pins on either component are
damaged, as this could damage pins on other
components. Replace parts as required.
The component might
have failed.
Enter the
tempshow
and
sensorShow
command to
determine the component status. If the component is
a CP blade or port blade, enter the
slotShow
command to determine the status. Replace the
component as necessary.
Diagnostics and Troubleshooting
136
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-08
Summary of Contents for DCX 8510-8
Page 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Page 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...