Blade
Port numbering
Trunking port groups
FC8-32E port
blade
• 0 through 15 from bottom to top on the
left set of ports.
• 16 through 31 from bottom to top on the
right set of ports.
• 0-7, 8-15, 16-23, and 24-31
FC8-48E port
blade
• 0 through 23 from bottom to top on the
left set of ports
• 24 through 47 from bottom to top on the
right set of ports.
• 0-7, 8-15, 16-23, 24-31, 32-39, and 40-47
FC8-64 port
blade
• 0 through 31 from bottom to top on the
left set of ports.
• 32 through 63 from bottom to top on the
right set of ports.
• 0-7, 8-15, 16-23, 24-31, 32-39, 40-47, 48-55,
and 56-63*.
(* - Octet 56-63 E_Port trunks are permitted
on the logical or base switch only.)
FC16-32 port
blade
• 0 through 15 from bottom to top on the
left set of ports.
• 16 through 31 from bottom to top on the
right set of ports.
• 0-7, 8-15, 16-23, and 24-31.
FC16-48 port
blade
• 0 through 23 from bottom to top on the
left set of ports.
• 24 through 47 from bottom to top on the
right set of ports.
• 0-7, 8-15, 16-23, 24-31, 32-39, and 40-47.
FC16-64 port
blade
• 0 through 63 from bottom to top.
These are QSFP ports 0-15. For
supported QSFPs, refer to
transceivers for the FC16-64 port blade
and the core blades
on page 44
• 0-7, 8-15, 16-23, 24-31, 32-39, 40-47, 48-55,
and 56-63.
FCOE10-24
blade
• 0 through 23 in two vertical rows from
bottom left to top right.
• NA
CR16-8 core
blade
ICL connectors are numbered from:
• 0 through 7 from bottom to top on the left
set of ports.
• 8 through 15 from bottom to top on the
right set of ports.
Each connector is a group of four 16-Gbps
ports. For supported QSFPs, refer to
Qualified transceivers for the FC16-64 port
blade and the core blades
• Trunk group 0: QSFP ports 0-3 and 8-11.
• Trunk group 1: QSFP ports 4-7 and 12-15.
NOTE
Individual FC ports within the same QSFP port
cannot form a trunk. A trunk has to comprise of
individual FC ports from different QSFP ports.
FS8-18 blade
• The 16 physical Fibre Channel ports on
this blade are numbered 0 through 15
from bottom to top .
• The two 10/100/1000 BaseT ports are
numbered from the bottom as GE0 and
GE1.
• 0-7 and 8-15
Installation of the Brocade DCX 8510-8
28
Brocade DCX 8510-8 Backbone Hardware Reference Manual
53-1002180-08
Summary of Contents for DCX 8510-8
Page 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Page 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Page 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...