X7-8-Install-IG100 Installation Guide
Brocade
®
X7-8 Director Hardware Installation Guide
The following table lists RASlog messages that can occur during the WWN card audit routine.
Table 29: RASlog Messages from WWN Card Audit
Error Message
Issue
[EM-1220]...M1, ERROR ... A problem
was found on one or both CID cards (x),
please run the wwnrecover tool to get more
information and recovery options.
Some kind of error or mismatch has been detected in the WWN
card audit.
[EM-1221], ... M1, INFO, ... A WWN card has
been inserted, a WWN verification audit will
be run to detect any mismatches or other
problems.
A second WWN card is enabled and the WWN card audit will
be run. If an error is detected during the audit, EM-1220 and
EM-1222 messages are generated.
[HIL-1650], CHASSIS, ERROR...Unable to
detect WWN cards in chassis. Access to WWN
halted...
The WWN card has been removed from the device. Replace the
card as soon as possible since the system is in a degraded state.
[EM-1222], ... M1, WARNING, ... A WWN
card access problem has been encountered,
please run the wwnrecover tool to get more
information and recovery options.
An error is detected during normal access to the WWN cards;
typically, one of the cards is corrupted or inaccessible.
Recovery is not possible. Please contact
Brocade Technical Support for replacement of
the corrupted or inaccessible WWN(s).
The license ID on the two WWN cards does not match.
The
wwnrecover
utility must be used to maintain data integrity when replacing one or both WWN cards using instructions
in the WWN card removal and replacement section. To run
wwnrecover
, log on as admin and enter the following
command:
switch:admin# wwnrecover
For more information on
wwnrecover
and command syntax, refer to the
Brocade Fabric OS Command Reference
Manual
.
X7-8-Install-IG100
155
Broadcom
Summary of Contents for Brocade X7-8
Page 212: ......