X7-8-Install-IG100 Installation Guide
Brocade
®
X7-8 Director Hardware Installation Guide
3. Enter the
slotShow -m
command and verify that all the installed cards are detected and that their status is
operational (enabled).
4. Verify that the device is functioning correctly by entering the
switchShow
command or the
switchStatusShow
command.
This
switchShow
command displays the device and port status information.
5. Verify that all the IP address information is correct by entering the
ipAddrShow
command and checking the results
against the IP information recorded in the
config-miscinfo.txt
file.
switch:admin> ipaddrshow
SWITCH
Ethernet IP Address: xxx.xxx.xxx.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: xxx.xxx.xxx.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: xxx.xxx.xxx.1
CP1
Ethernet IP Address: xxx.xxx.xxx.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: .1
Backplane IP address of CP0 : 10.0.0.4
Backplane IP address of CP1 : 10.0.0.5
switch:admin>switch:admin>
Verifying Correct Configuration of the Fabric
Copy the command outputs from this section into a file. You must be logged in with Admin privileges.
1. Create an after process SAN profile by entering the following commands and copying the output to a text file named
SANafter.txt
:
•
fabricShow
•
lscfg --show
(if using the Virtual Fabrics feature)
•
nsAllShow
•
nsShow
•
switchShow
switch:admin> nsshow
Type Pid COS PortName NodeName TTL(sec)
N 020f00; 3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
Fabric Port Name: 20:0f:00:60:69:90:03:f0
<output truncated>
switch:admin> nsallshow
{
020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
switch:admin> switchshow