5.15
Checking the water inflow
Prerequisite:
Left side panel has been removed.
1. Check the fault memory for filling faults.
2.
The customer service test programme measures the inlet
water flow. See Testing / Measures - Testing the inlet water
flow. (0.5 bar;8 l/min)
Start the customer service test programme.
3. When the programme reaches the point ‘water level in the unit’, perform a
visual inspection of the water inlet system and check that water is flowing
correctly into the water inlet system / heat exchanger.
4.
0
If the water inlet system or heat exchanger is damaged or leaks
► replace the water inlet system or heat exchanger.